Regular and narrow-band RGB cameras are recently explored for contactless SpO2 monitoring. Regular RGB cameras with cross-band overlap provide a high signal-to-noise-ratio (SNR) in measuring the photoplethysmographic signals but possess high dependency on the spectra of incident light, whereas narrow-band RGB cameras have better spectral independence but lower SNR especially in dim lighting conditions, such as in the neonatal intensive care unit (NICU). This paper proposes a notch RGB camera based SpO2 measurement approach that uses an optical notch filter to attenuate the wavelengths of 580-605 nm of a regular RGB camera to improve the spectral independence while maintaining high SNR in signal measurement. The proposed setup was validated in the lab condition (e.g. dark chamber) against the existing solutions for visible-light based camera-SpO2 measurement and further verified in the NICU on preterm infants. The clinical trial conducted in the NICU with 22 preterm infants shows that the notch RGB camera can achieve a mean absolute error (MAE) less than 4% for SpO2 measurement. This is the first showcase of continuous monitoring of absolute camera-SpO2 values in the NICU.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
11:39Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...