Related Experiment Video
Updated: Jul 5, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Factors affecting radiographers' use of dose-reduction measures
May Bazzi1, Shilan Shamon Afram2, Irine Maghanwi Ndipen2
1Department of Health and Care Sciences, University of Gothenburg, Gothenburg, Sweden.
None:
This study investigates radiographers' views on implementing dose-reduction measures, with a focus on verifying patient identity and pregnancy status, practising gonad shielding in men and using compression. An electronic questionnaire was distributed to radiographers working in general radiography and/or computed tomography. The questionnaire was based on factors from a framework for analysing risk and safety in clinical medicine. Ordered logistic regressions were used to analyse associations among factors and use of dose-reduction measures. In total, 466 questionnaires were distributed and 170 radiographers (36%) completed them. Clear instructions and routines, support from colleagues, knowledge and experience, a strong safety culture, managerial support and access to proper equipment influence the likelihood of using dose-reduction measures. The strongest associations were found between support from colleagues and verifying pregnancy status (OR = 5.65,P= 0.026), safety culture and use of gonad shielding (OR = 2.36,P= 0.042), and having enough time and use of compression (OR = 2.11,P= 0.003). A strong safety culture and a supportive work environment appears to be essential for the use of dose-reduction measures, and education, training and stress management can improve utilisation of dose-reduction measures.
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Factors Affecting Body Temperature
Factors may include:
X-ray Imaging