Related Experiment Video
Updated: Aug 21, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Cost-benefit analysis of intraoperative neuromonitoring for cardiac surgery
Bhav Jain1, Faraan O Rahim2, Parthasarathy D Thirumala3
1Stanford University School of Medicine, Stanford, CA, United States; Massachusetts Institute of Technology, Cambridge, MA, United States.
Background:
Intraoperative neuromonitoring (IONM) can detect large vessel occlusion (LVO) in real-time during surgery. The aim of this study was to conduct a cost-benefit analysis of utilizing IONM among patients undergoing cardiac surgery.
Methods:
A decision-analysis tree with terminal Markov nodes was constructed to model functional outcome, as measured via the modified Rankin Scale (mRS), among 65-year-old patients undergoing cardiac surgery. Our cost-benefit analysis compares the use of IONM (electroencephalography and somatosensory evoked potential) against no IONM in preventing neurological complications from perioperative LVO during cardiac surgery. The study was performed over a lifetime horizon from a societal perspective in the United States. Base case and one-way probabilistic sensitivity analyses were performed.
Results:
At a baseline LVO rate of 0.31%, the mean attributable lifetime expenditure for IONM-monitored cardiac surgeries relative to unmonitored cardiac surgeries was $1047.41 (95% CI, $742.12 - $1445.10). At a critical LVO rate of approximately 3.67%, the costs of both monitored and unmonitored cardiac surgeries were the same. Above this critical rate, implementing IONM became cost-saving. On one-way sensitivity analysis, variation in LVO rate from 0% - 10% caused lifetime costs attributable to receiving IONM to range from $1150.47 - $29404.61; variations in IONM cost, percentage of intervenable LVOs, IONM sensitivity, and mechanical thrombectomy cost exerted comparably minimal influence over lifetime costs.
Discussion:
We find considerable cost savings favoring the use of IONM under certain parameters corresponding to high-risk patients. This study will provide financial perspective to policymakers, clinicians, and patients alike on the appropriate use of IONM during cardiac surgery.