Shift Volume Directly Impacts Neuroradiology Error Rate at a Large Academic Medical Center: The Case for Volume
Vladimir Ivanovic1, Kenneth Broadhead2, Yu-Ming Chang3
1From the Department of Radiology, Section of Neuroradiology (V.I., J.F.H., R.B.), Medical College of Wisconsin, Milwaukee, Wisconsin Vladimir.ivanovic@yahoo.com.
Background And Purpose:
Unlike in Europe and Japan, guidelines or recommendations from specialized radiological societies on workflow management and adaptive intervention to reduce error rates are currently lacking in the United States. This study of neuroradiologic reads at a large US academic medical center, which may hopefully contribute to this discussion, found a direct relationship between error rate and shift volume.
Materials And Methods:
CT and MR imaging reports from our institution's Neuroradiology Quality Assurance database (years 2014-2020) were searched for attending physician errors. Data were collected on shift volume specific error rates per 1000 interpreted studies and RADPEER scores. Optimal cutoff points for 2, 3 and 4 groups of shift volumes were computed along with subgroups' error rates.
Results:
A total of 643 errors were found, 91.7% of which were clinically significant (RADPEER 2b, 3b). The overall error rate (errors/1000 examinations) was 2.36. The best single shift volume cutoff point generated 2 groups: ≤ 26 studies (error rate 1.59) and > 26 studies (2.58; OR: 1.63, P < .001). The best 2 shift volume cutoff points generated 3 shift volume groups: ≤ 19 (1.34), 20-28 (1.88; OR: 1.4, P = .1) and ≥ 29 (2.6; OR: 1.94, P < .001). The best 3 shift volume cutoff points generated 4 groups: ≤ 24 (1.59), 25-66 (2.44; OR: 1.54, P < .001), 67-90 (3.03; OR: 1.91, P < .001), and ≥ 91 (2.07; OR: 1.30, P = .25). The group with shift volume ≥ 91 had a limited sample size.
Conclusions:
Lower shift volumes yielded significantly lower error rates. The lowest error rates were observed with shift volumes that were limited to 19-26 studies. Error rates at shift volumes between 67-90 studies were 226% higher, compared with the error rate at shift volumes of ≤ 19 studies.