Background:
Neonatal sepsis remains a leading cause of mortality in neonatal units. Neonatologist-performed echocardiography (NPE) offers the potential for early detection of sepsis-associated cardiovascular dysfunction. This review examines available echocardiographic findings in septic neonates.
Methods:
Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we systematically reviewed prospective observational, cross-sectional, case control, and cohort studies on septic newborns with echocardiographic assessments from PubMed, Scopus and Embase. Quality assessment employed the Newcastle-Ottawa Scale, with results analyzed descriptively.
Results:
From an initial pool of 1663 papers, 12 studies met inclusion criteria after relevance screening and eliminating duplicates/excluded studies. The review encompassed 438 septic newborns and 232 controls. Septic neonates exhibited either increased risk of pulmonary hypertension or left ventricular diastolic dysfunction, and a warm shock physiology characterized by higher cardiac outputs.
Discussion:
The included studies exhibited heterogeneity in sepsis definitions, sepsis severity scores, echocardiographic evaluations, and demographic data of newborns. Limited sample sizes compromised analytical interpretability. Nonetheless, this work establishes a foundation for future high-quality echocardiographic studies.
Conclusion:
Our review confirms that septic neonates show significant hemodynamic changes that can be identified using NPE. These findings underscore the need for wider NPE use to tailor hemodynamics-based strategies within this population.
Impact:
1. Our study emphasizes the value of neonatologist-performed echocardiography (NPE) as a feasible tool for identifying significant hemodynamic changes in septic neonates. 2. Our study underscores the importance of standardized echocardiographic protocols and frequent monitoring of cardiac function in septic neonates. 3. The impact of the study lies in its potential to increase researchers' awareness for the need for more high-quality echocardiographic data in future studies. By promoting wider use of NPE, neonatologists can more accurately assess the hemodynamic status of septic newborns and tailor treatment approaches, potentially improving patient outcomes.
More Related Videos
11:27A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
07:13Author Spotlight: Advancing Neonatal Cardiac Diagnostics with Echocardiography-Derived Blood Speckle Imaging
Published on: December 22, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...