Evaluation of Drug Sorption to PVC- and Non-PVC-based Tubes in Administration Sets Using a Pump
Published on: March 11, 2017
Drug compatibility with various closed intravenous infusion containers
Chang-Yu Zhu1,2, Hui-Ying Zuo1, Hong-Lin Li1
1Department of Pharmacy, Sichuan Academy of Medical Sciences, Sichuan Provincial People's Hospital, Chengdu, Sichuan Province, China.
This study found that closed intravenous infusion containers are compatible with common injections. Optimizing the preparation process is key to reducing particulate contaminants for improved medication safety.
Area of Science:
- Pharmaceutical Science
- Materials Science
Background:
- Medication safety is paramount in clinical practice.
- Intravenous (i.v.) infusion containers play a critical role in drug delivery.
- Ensuring drug compatibility with infusion containers is essential.
Purpose of the Study:
- To systematically compare drug compatibility with various closed i.v. infusion containers.
- To provide a reference for selecting superior infusion containers.
- To enhance medication safety in clinical settings.
Main Methods:
- Evaluated four common injections (ceftazidime, pantoprazole sodium, ambroxol hydrochloride, edaravone).
- Tested three types of closed i.v. infusion containers (non-PVC, upright polypropylene, inner sealed polypropylene).
- Assessed particle counts, pH, physical properties, and drug concentrations over time using light obscuration and HPLC.
Main Results:
- Non-PVC bags showed higher particle counts in some cases compared to polypropylene bags.
- Particle counts increased significantly in diluted injections within all containers, particularly for small particles.
- pH, physical properties, and drug concentrations remained stable across all tested containers and injections.
Conclusions:
- All tested closed i.v. infusion containers demonstrated good compatibility with the evaluated injections.
- Chinese-manufactured infusion containers meet international quality standards.
- Optimization of intravenous admixture preparation is necessary to minimize particulate contaminants.
Related Concept Videos
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...