A two-terminal fault location method for gas switch prefire in linear transformer driver
Zhenbo Wan1, Weidong Ding1, Fengju Sun2
1State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China.
Abstract:
Large-scale linear transformer drivers (LTDs) are composed of numerous high-power gas switches, and switch prefire is a frequent operational fault. To detect and locate the faulty switch accurately and efficiently, a two-terminal location method is proposed. A B-dot sensor is integrated on the gas switch's shell to collect the discharging signal. All the B-dot sensors are connected in parallel through cables of equal length. The fault position can be determined by the time delay of the signals at the two terminals. A diode is inserted between the B-dot sensor's coil and the cable core to ensure low-loss transmission of the signal. Two methods are applied in fault location, including time-of-arrival (TOA) and time reversal (TR). For the TOA method, an energy criterion and a phase criterion are applied and compared. The accuracy of the energy criterion is greatly influenced by the signal-to-noise ratio, while the phase criterion requires a reasonable estimate of the actual delay to account for the impact of phase periodicity. The TR method based on a precise simulation model is established, which demonstrates high precision in location. The TR method has been tested and validated on a single stage LTD module. Moreover, the location method for double switches prefire is discussed theoretically. The method proposed in this paper will be helpful to improve the efficiency of the commissioning, operation, and maintenance of the large-scale LTD devices.
More Related Videos
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Related Concept Videos
Power System Three-Phase Short Circuits
Directional Relays
Fault Types
For line-to-line faults occurring between phases B and C, the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Circuit Breaker and Fuse Selection
In high-voltage systems,...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...