Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Estimated Pulse Wave Velocity Predicts All-Cause and Cardiovascular-Cause Mortality in Individuals With
Yi Shi1, Li-Da Wu1, Xiao-Hua Feng2
1Department of Cardiology, Nanjing First Hospital, Nanjing Medical University.
Background:
This study aimed to investigate the association between estimated pulse wave velocity (ePWV) and mortality outcomes among individuals with hypertension.
Methods And Results:
Based on the National Health and Nutrition Examination Survey (NHANES) 1999-2018, a total of 14,396 eligible participants with hypertension were enrolled. The ePWV was calculated using the equation based on blood pressure and age. The mortality outcomes of included participants were directly acquired from the National Death Index database. The multivariable Cox regression analysis was used to examine the relationship between ePWV and mortality outcomes. Moreover, the restricted cubic spline (RCS) was also used to explore this relationship. Receiver operating characteristics curves (ROC) were adopted to evaluate the prognostic ability of ePWV for predicting mortality outcomes of patients with hypertension. The median follow-up duration was 10.8 years; individuals with higher an ePWV had higher risks of mortality from both all causes (HR: 2.79, 95% CI: 2.43-3.20) and cardiovascular diseases (HR: 3.41, 95% CI: 2.50-4.64). After adjusting for confounding factors, each 1 m/s increase in ePWV was associated with a 43% increase in all-cause mortality risk (HR: 1.43, 95% CI: 1.37-1.48) and a 54% increase in cardiovascular mortality risk (HR: 1.54, 95% CI: 1.43-1.66).
Conclusions:
This study indicates that ePWV is a novel prognostic indicator for predicting the risks of mortality among patients with hypertension.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Measurement of Blood Pressure
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...