Reference free auscultation quality metric and its trends
Annapurna Kala1, Eric D McCollum2, Mounya Elhilali1
1Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA.
Abstract:
Stethoscopes are used ubiquitously in clinical settings to 'listen' to lung sounds. The use of these systems in a variety of healthcare environments (hospitals, urgent care rooms, private offices, community sites, mobile clinics, etc.) presents a range of challenges in terms of ambient noise and distortions that mask lung signals from being heard clearly or processed accurately using auscultation devices. With advances in technology, computerized techniques have been developed to automate analysis or access a digital rendering of lung sounds. However, most approaches are developed and tested in controlled environments and do not reflect real-world conditions where auscultation signals are typically acquired. Without a priori access to a recording of the ambient noise (for signal-to-noise estimation) or a reference signal that reflects the true undistorted lung sound, it is difficult to evaluate the quality of the lung signal and its potential clinical interpretability. The current study proposes an objective reference-free Auscultation Quality Metric (AQM) which incorporates low-level signal attributes with high-level representational embeddings mapped to a nonlinear quality space to provide an independent evaluation of the auscultation quality. This metric is carefully designed to solely judge the signal based on its integrity relative to external distortions and masking effects and not confuse an adventitious breathing pattern as low-quality auscultation. The current study explores the robustness of the proposed AQM method across multiple clinical categorizations and different distortion types. It also evaluates the temporal sensitivity of this approach and its translational impact for deployment in digital auscultation devices.
Related Concept Videos
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...