Research on Residual-Current Measurement System of Substation Considering Magnetic Shielding Effect

Jinhu Tian1, Yu Xu1, Yang Yang2

  • 1State Grid Chongqing Electric Power Company Ultra High Voltage Branch, Chongqing 400039, China.

PubMed

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
88
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current01:14

Diamagnetic Shielding of Nuclei: Local Diamagnetic Current

An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
861
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
143
Motional Emf01:22

Motional Emf

Magnetic flux depends on three factors: the strength of the magnetic field, the area through which the field lines pass, and the field's orientation with respect to the surface area. If any of these quantities vary, a corresponding variation in magnetic flux occurs. If the area through which the magnetic field lines are passing changes, then the magnetic flux also changes. This change in the area can be of two types: the flux through the rectangular loop increases as it moves into the...
3.2K
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
2.5K
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
102