Energy conservation of HVAC systems in isolation rooms using heat pipe heat exchangers
Fazri Amir1,2, Samsul Rizal3, Razali Thaib3
1Doctoral Program, School of Engineering, Universitas Syiah Kuala, Banda Aceh, 23111, Indonesia.
Abstract:
Isolation rooms are crucial in healthcare facilities to prevent the spread of infectious diseases. Infectious diseases can be transmitted to humans from humans or through animals known as zoonoses. With the increase in the number of COVID-19 cases, isolation rooms have become one of the most critical facilities in hospitals. Maintaining the correct temperature and humidity in these isolation rooms is a challenge, considering the heating, ventilation, and air conditioning (HVAC) systems that continuously consume large amounts of energy. With the application of energy conservation methods, the total energy consumption of HVAC systems can be reduced. Many studies have shown that the heat pipe heat exchanger (HPHE) technology can contribute significantly to energy savings using HVAC systems. In this study, the effectiveness of an HPHE on an HVAC system in an isolation room was examined, and the total energy reduction was quantified. The HPHE consisted of two rows with ten heat pipes in each row, arranged in a staggered configuration with fresh air temperature and mass flow variations. The inlet fresh air temperatures varied at 32, 35, 37, and 40 °C and fresh air velocities at 1.2, 1.6, 2.2, and 2.6 m/s. Using a chiller, the inlet fresh air was cooled to a comfortable temperature zone, approximately 24.4-25.2 °C, in the isolation room. Notably, higher velocities decreased the effectiveness of the HPHE. An increase in the flow rate enhanced the system, thereby improving the heat recovery value. The increase in the inlet fresh air temperature from 32 °C, that yielded an energy saving of 1.23 W, to 40 °C, resulted in a further energy saving of 1.85 W. The application of the HPHE in the HVAC system in isolation rooms represents a significant innovation that contributes to a reduction in total energy consumption.
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Cyclic Processes And Isolated Systems
In the case of a non-isolated system, the change in the internal energy is zero only if the process is cyclic. A thermodynamic process is considered cyclic if the system undergoes a series of changes and returns to its initial state.
Consider a cyclic process that returns to its initial state, undergoing a four-step process. The heat transfer along each...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Mechanism of heat transfer
The Carnot Cycle