Mass spectrometric study of low energy Cs+ ion-induced sputtered fragmentation of PADC polymer
Muhammad Sabbtain Abbas1, Bilal Jehanzaib2, Shahzad Hussain2
1Centre for Advanced Studies in Physics, Government College University, Lahore, Pakistan.
Abstract:
In this study, low-energy cesium (Cs+ ) ion-induced sputtered fragmentation of poly allyl diglycol carbonate (PADC) was investigated using mass spectrometry. The collision-induced dissociation mechanism revealed emission of various fragments, including monoatomic (H- , C1 - , O1 - ), diatomic (C2 - ), and multiatomic (C3 - , CO2 - , C2 O2 - , C3 O2 - ) species within the Cs+ ion energy range of 1-5 keV. The anion current of these fragments exhibited a linear increase with rising incident Cs+ ion energy, indicating a corresponding rise in fragment abundance. Analysis of normalized yield indicated that at 1 keV incident energy, the dominant fragment was monoatomic hydrogen (H- ), followed by diatomic carbon (C2 - ), monoatomic carbon (C1 - ), and monoatomic oxygen (O1 - ). Although C2 - remained dominant up to 5 keV, other fragments exhibited varying normalized yields at different ion energy steps. The sputter yield estimation revealed that monoatomic hydrogen (H- ) and diatomic carbon (C2 - ) exhibited the highest yields, increasing exponentially beyond 3 keV, while multiatomic fragments like C3 - , CO2 - , C2 O2 - , and C3 O2 - displayed the lowest yields. The sputter dissociation mechanism pointed to dehydrogenation, chain scission, and bond breakage as the primary processes during low-energy Cs+ ion impact. Postsputtering Scanning Electron Mircoscope (SEM) micrographs show craters, pits, and micropores on the PADC surface, indicating significant surface degradation. X-ray Diffraction (XRD) spectra exhibited reduced diffraction intensity, while Fourier Transform Infrared Spectroscopy (FTIR) analysis indicated the absence of molecular bands in the IR spectrum, confirming extensive surface damage due to Cs+ ion-induced sputtering.
Related Concept Videos
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example,...
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Mass Spectrometry: Long-Chain Alkane Fragmentation
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Alkene Fragmentation