Related Experiment Video
Updated: Jul 4, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Performance of angle shear connectors for U-shaped steel concrete infilled composite beams
Muhammad Haroon1, Hee-Du Lee1, Kyung-Jae Shin2
1Regional Center for Land, Infrastructure, and Transport Technology, Kyungpook National University, Daegu, 41566, South Korea.
Abstract:
The current design codes i.e. AISC 360-16, CSA-S16-19, EC-04 etc. provide empirical relationships to estimate the capacity of shear connectors which were developed based on pushout tests of headed studs and channels connectors in exposed type sections. Therefore, these equations may result inaccurate predictions for strength of connectors in infilled-type sections. This study presents a detailed experimental study investigating the performance of angle connectors in composite sections. The testing program consisted two series of pushout tests. A total of 36 specimens were tested, considering the influence of several important parameters i.e. the length (L), height (h), and web-thickness (t) of angle connector, length of the weld () and the direction of shear connector (forward/backward) etc. The tests results demonstrated that with increasing connector height h and thickness, the maximum load Pmax and slip were increased. The connector direction didn't change much the load-slip behavior. The prediction accuracy of the existing shear capacity models was evaluated by comparing the predictions with experimental results. The current equations were noticed to be highly inconsistent in predicting the shear capacity of angle connectors, especially in case of infilled type sections. When the entire length of connector was taken as the effective length, the models overestimated the shear capacity. While in case when the welding length was taken as effective length in calculations, the models underestimated the shear strength of angle connectors.
Related Concept Videos
Shear on the Horizontal Face of a Beam Element
Reinforcements in Concrete
Design Example: Distributing Reinforcements in Concrete Sections
Steel Fastening Techniques
Rivets are cylindrical steel fasteners with a specially designed head. During application, rivets are heated until white-hot and then inserted through pre-drilled holes in the steel sections. A pneumatic hammer is used to shape the exposed end into a second head, securing the sections together.
Bolting is another...
Shearing Stresses in a Beam: Problem Solving
Prestressed Concrete