Early and mid-term outcomes after aortic valve replacement using a novel tissue bioprosthesis: a systematic review
Davorin Sef1, Myat Soe Thet2, Tomislav Klokocovnik3
1Department of Cardiac Surgery, University Hospitals of Leicester, Leicester, UK.
Objectives:
While current data show a clear trend towards the use of bioprosthetic valves during aortic valve replacement (AVR), durability of bioprosthetic valves remains the most important concern. We conducted a 1st systematic review of all available evidence that analysed early and mid-term outcomes after AVR using the Inspiris RESILIA™ bioprosthesis.
Methods:
A systematic literature search was performed to identify all relevant studies evaluating early and mid-term outcomes after AVR using the Inspiris RESILIA bioprosthesis and including at least 20 patients with no restriction on the publication date. Subgroup meta-analysis was performed to compare Inspiris RESILIA and PERIMOUNT Magna Ease bioprosthesis and to pool the early postoperative mortality and stroke rates.
Results:
A total of 416 studies were identified, of which 15 studies met the eligibility criteria. The studies included a total of 3202 patients with an average follow-up of up to 5.3 years. The average age of patients across the studies was 52.2-75.1 years. Isolated AVR was performed in 39.0-86.4% of patients. In-hospital or 30-day postoperative mortality was 0-2.8%. At the mid-term follow-up, freedom from all-cause mortality was up to 85.4%. Among studies with mid-term follow-up, trace/mild paravalvular leak was detected in 0-3.0%, while major paravalvular leak was found only in up to 2.0% of patients. No statistically significant differences in terms of mortality (P = 0.98, odds ratio 1.02, 95% confidence interval 0.36-2.83) and stroke (P = 0.98, odds ratio 1.01, 95% confidence interval 0.38-2.73) between the Inspiris RESILIA bioprosthesis and PERIMOUNT Magna Ease bioprosthesis were observed in the subgroup meta-analysis.
Conclusions:
Mid-term data on the safety and haemodynamic performance of the novel aortic bioprosthesis are encouraging. Further comparative studies with other bioprostheses and longer follow-up are still required to endorse durability and safety of the novel bioprosthesis.