Open-Circuit Fault Diagnosis of T-Type Three-Level Inverter Based on Knowledge Reduction
Xiaojuan Chen1, Zhaohua Zhang1
1School of Electronic Information Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Abstract:
Compared with traditional two-level inverters, multilevel inverters have many solid-state switches and complex composition methods. Therefore, diagnosing and treating inverter faults is a prerequisite for the reliable and efficient operation of the inverter. Based on the idea of intelligent complementary fusion, this paper combines the genetic algorithm-binary granulation matrix knowledge-reduction method with the extreme learning machine network to propose a fault-diagnosis method for multi-tube open-circuit faults in T-type three-level inverters. First, the fault characteristics of power devices at different locations of T-type three-level inverters are analyzed, and the inverter output power and its harmonic components are extracted as the basis for power device fault diagnosis. Second, the genetic algorithm-binary granularity matrix knowledge-reduction method is used for optimization to obtain the minimum attribute set required to distinguish the state transitions in various fault cases. Finally, the kernel attribute set is utilized to construct extreme learning machine subclassifiers with corresponding granularity. The experimental results show that the classification accuracy after attribute reduction is higher than that of all subclassifiers under different attribute sets, reflecting the advantages of attribute reduction and the complementarity of different intelligent diagnosis methods, which have stronger fault-diagnosis accuracy and generalization ability compared with the existing methods and provides a new way for hybrid intelligent diagnosis.
Related Concept Videos
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Fault Types
For line-to-line faults occurring between phases B and C, the...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...