Angela Alfarano1, Roberto Marzollo2, Maria Ilaria Bosio2
1Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy. angela.alfarano@asst-spedalicivili.it.
Abstract:
Neonatologist Performed Echocardiography (NPE) is one of the emerging technologies used to evaluate Systemic Blood Flow (SBF) in term and preterm infants. Right Ventricular Output (RVO) can assess SBF correctly in the absence of significant interatrial or interventricular shunts, even in the presence of a large patent ductus arteriosus (PDA), but only few studies evaluated inter-observer variability in neonates. Furthermore, measuring pulmonary peak flow (PF) provides a simple screening tool for low SBF state, easier and faster to perform than RVO; no previous studies evaluated PF inter-observer variability. To describe inter-observer variability of RVO and PF measurement in neonates. We conducted a prospective observational study in term and preterm infants admitted to the Neonatal Intensive Care Unit (NICU). Echocardiographic examinations were performed by two expert neonatologists, blinded to each other. Recordings were analyzed off-line to assess RVO and PF variability between observers. We analyzed a cohort of 33 neonates, 17 of them born prematurely. Inter-observer mean difference for RVO was 22,1 mL/kg/min (p = 0.005); the biggest discrepancy was due to pulmonary valve diameter measurement (p = 0.0001). Inter-observer mean difference for PF measurement was not statistically significant. We found a statistically significant inter-observer variability for RVO measurement, consistent with previous reports; PF instead showed low inter-observer variability. For this reason, PF could be evaluated in future studies as a surrogate for RVO in both term and preterm infants, especially in emergency conditions or in presence of a poor echocardiographic window.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...