Related Experiment Video
Updated: Jul 3, 2025

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Statewide Initiative to Reduce Patient Radiation Doses During Percutaneous Coronary Intervention
Ryan D Madder1, Milan Seth2, Kathleen Frazier2
1Frederik Meijer Heart and Vascular Institute, Division of Cardiovascular Medicine, Corewell Health West, Grand Rapids, MI (R.D.M.).
Background:
Improved radiation safety practices are needed across hospitals performing percutaneous coronary intervention (PCI). This study was performed to assess the temporal trend in PCI radiation doses concurrent with the conduct of a statewide radiation safety initiative.
Methods:
A statewide initiative to reduce PCI radiation doses was conducted in Michigan between 2017 and 2021 and included focused radiation safety education, reporting of institutional radiation doses, and implementation of radiation performance metrics for hospitals. Using data from a large statewide registry, PCI discharges between July 1, 2016, and July 1, 2022, having a procedural air kerma (AK) recorded were analyzed for temporal trends. A multivariable regression analysis was performed to determine whether declines in procedural AK over time were attributable to changes in known predictors of radiation doses.
Results:
Among 131 619 PCI procedures performed during the study period, a reduction in procedural AK was observed over time, from a median dose of 1.46 (0.86-2.37) Gy in the first year of the study to 0.97 (0.56-1.64) Gy in the last year of the study (P<0.001). The proportion of cases with an AK ≥5 Gy declined from 4.24% to 0.86% over the same time period (P<0.0001). After adjusting for variables known to impact radiation doses, a 1-year increase in the date of PCI was associated with a 7.61% (95% CI, 7.38%-7.84%) reduction in procedural AK (P<0.0001).
Conclusions:
Concurrent with the conduct of a statewide initiative to reduce procedural radiation doses, a progressive and significant decline in procedural radiation doses was observed among patients undergoing PCI in the state of Michigan.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...