Related Experiment Video
Updated: Jul 3, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Optical and aberrometric evaluation of a new enhanced monofocal intraocular lens with isofocal optic design
Lidia Pérez-Sanz1,2, Carla Charbel1, Francisco Poyales2
1Optometry and Vision Department, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
Purpose:
To evaluate the optical and aberrometric outcomes of an enhanced monofocal intraocular lens (ISOPure) compared with those of a standard monofocal lens (MicroPure) having the same platform and material.
Methods:
A prospective, comparative and randomised clinical study. A total of 28 eyes of 28 patients were randomly assigned to either group. Monocular visual acuity (VA) was measured at distance and intermediate under photopic and mesopic conditions. Aberrometry was analysed for 3.0-, 4.0-, 4.5- and 5.0 mm pupils. The contrast sensitivity defocus curve was measured for 3.0- and 4.5-mm pupils, while the modulation transfer function (MTF) and Strehl ratio (SR) were assessed with a double-pass system. All measurements were performed monocularly 3 months after surgery.
Results:
No significant differences were found for distance VA. Under photopic conditions, intermediate VA was better with the ISOPure lens, while no significant differences were found between the lenses under mesopic conditions. Internal and total aberrations were higher for the ISOPure lens. No significant differences were found for corneal aberrations. Additionally, both the contrast sensitivity defocus curve and optical quality showed similar behaviour for each lens, with the MTF cut-off frequency exceeding 30 c/deg in both cases.
Conclusion:
The isofocal ISOPure lens enhanced intermediate VA without affecting distance VA under photopic conditions. Moreover, there were no significant differences in visual quality between the ISOPure and MicroPure lenses, despite the former exhibiting higher internal and total aberrations than the monofocal model.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Focusing of Light in the Eye
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Confocal Fluorescence Microscopy