Related Experiment Video
Updated: Jul 3, 2025

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Facile preparation of embedded polar group-containing pentafluorophenyl stationary phases for highly selective
Abul K Mallik1, Lidia Montero2, Sven W Meckelmann3
1Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstr. 5, 45141 Essen, Germany; Department of Applied Chemistry and Chemical Engineering, University of Dhaka, Dhaka 1000, Bangladesh.
Abstract:
Pentafluorophenyl (PFP) stationary phase is one of the most important phases after the C18 phase in terms of its applications. Three embedded polar groups (EPG)-containing stationary phases were newly synthesized to act the EPGs as additional interaction sites. The silica surface was initially modified with (3-aminopropyl)trimethoxysilane (APS). The APS-modified silicas were coupled with 2,3,4,5,6-pentafluorobenzoic acid, 2,3,4,5,6-pentafluorophenylacetic acid, and 2,3,4,5,6-pentafluoro-anilino(oxo)acetic acid to obtain Sil-PFP-BA, Sil-PFP-AA, and Sil-PFP-AN phases, respectively. The new phases were characterized by elemental analysis, ATR-FTIR, scanning electron microscopy (SEM), and thermogravimetric analysis (TGA). The phases were evaluated with the Tanaka and Neue tests in reversed-phase liquid chromatography (RPLC). In addition, they were characterized as hydrophilic phases by the Tanaka test protocol used in hydrophilic interaction chromatography (HILIC) separation mode. The Sil-PFP-AA phase showed the highest molecular shape selectivity in RPLC, while Sil-PFP-AN achieved the highest separability in HILIC compared to the commercial PFP reference column. The Sil-PFP-AA phase was successfully applied for the analysis of capsaicinoids from real samples of fresh chili peppers (Capsicum spp.) in RPLC and the Sil-PFP-AN phase for vitamin C (ascorbic acid) in HILIC.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...