Related Experiment Video
Updated: Aug 19, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium
Faeze Masoomi1, Farhang Mahboub2
1Department of Prosthodontic, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz. faezeh.dds.94@gmail.com.
Abstract:
Success/failure of dental implants depends on stress transfer and distribution at the bone-implant interface. This study aimed to assess the stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional (3D) finite element analysis (FEA). In this FEA, a geometric model of an edentulous maxilla, Zimmer screw-vent tantalum and solid titanium implants were modelled. Four models with the all-on-four concept were designed. The fifth model had 6 vertical implants (all-on-six). Two different implant types (porous tantalum and solid titanium) were modelled to yield a total of 10 models, and subjected to 200 N bilateral vertical load. Pattern of stress distribution and maximum von Mises stress values in cancellous and cortical bones around implants were analysed. In tantalum models, the effect of increasing the distal tilting of posterior implants was comparable to the effect of increasing the number of implants to 6 on von Mises stress values in cortical bone. However, in cancellous bone, the effect of increasing the tilting of posterior implants on stress was slightly greater than the effect of increasing the number of implants to 6. In solid titanium models, the effect of both of the abovementioned parameters was comparable on stress in cancellous bone; but in cortical bone, the effect of increasing the implant number was slightly greater on stress reduction. Despite similar pattern of stress distribution in bone around implants, higher maximum von Mises stress values around tantalum implants indicate higher stress transfer capacity of this type of implant to the adjacent bone, compared with solid titanium implants.
More Related Videos
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Generalized Hooke's Law
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Plastic Deformations of Members with a Single Plane of Symmetry
Transformation of Plane Stress
Three-Dimensional Analysis of Strain