A high-resolution time-frequency analysis technique based on bi-directional squeezing and its application in fault
Yunlong Ma1, Gang Yu2, Tianran Lin3
1School of Electrical Engineering, University of Jinan, Jinan 250022, China.
Abstract:
Most of the signals in the field of industrial engineering are nonstationary signals, and the accurate description of the time-frequency (TF) characteristics of nonstationary signals is important for the advancement of industrial engineering. Instantaneous frequency (IF) and group delay (GD) are common TF features used to describe nonstationary signals. Time-reassigned synchrosqueezing transform and synchrosqueezing transform are two TF analysis tools that can accurately characterize the GD and IF of nonstationary signals by squeezing the TF coefficients in the time direction and frequency direction, respectively. However, it is difficult for such two techniques to accurately characterize IF and GD simultaneously. A novel method called time-frequency squeezing transform is introduced in this paper to conquer this drawback. The technique first uses the short-time Fourier transform to calculate the time-frequency representation (TFR) of a signal, and then divides the TFR into two parts according to a chirp rate estimator. The subdivided TFR parts are then squeezed in the frequency and time directions to accurately characterize the IF and GD, respectively, and the two squeezed results are added to form a high-resolution result. The effectiveness of the proposed technique is demonstrated with numerical and experimental signals.
More Related Videos
00:05Crack Monitoring in Resonance Fatigue Testing of Welded Specimens Using Digital Image Correlation
Published on: September 29, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Power System Three-Phase Short Circuits
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Fault Types
For line-to-line faults occurring between phases B and C, the...
Thin-Walled Hollow Shafts