Related Experiment Video
Updated: Jul 2, 2025

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Variability in Practice and Implementation of Oxygen Target Saturation Policies in United States' Neonatal Intensive
Pratik Parikh1, Robert D White2, Veeral N Tolia3,4
1Department of Pediatrics, Baylor College of Medicine, Christus Children Hospital, San Antonio, Texas.
Objective:
This study aimed to describe target oxygen saturation (SpO2) ranges used for premature infants in United States' neonatal intensive care units (NICUs) and to describe if these target SpO2 ranges have changed in recent years.
Study Design:
A 29-question survey focused on target SpO2 practices and policies was distributed via the NICU medical directors listservs for the American Academy of Pediatrics Section of Neonatal-Perinatal Medicine and Pediatrix Medical Group between August and October of 2021. Results were collected via Research Electronic Data Capture (REDCap).
Results:
We received responses representing 170 unique, levels 2, 3, and 4 NICUs from 36 states. Most NICUs (130, 78%) have recently changed their SpO2 targets in response to target SpO2 clinical trials. Over time, the most commonly reported target SpO2 range has shifted from 88-92% to 90-95. Of NICUs that changed limits, the most common lower SpO2 limits increased from 88 to 90% and the upper SpO2 limits changed from 92 to 95%. The interquartile range for lower SpO2 limit shifted from 85-88% to 88-90% and the IQR for upper SpO2 limit decreased from 92-95 to 94-95%. Most NICUs had designated conditions that would allow for deviations from standard target SpO2 ranges. These most commonly include pulmonary hypertension (152, 95%), severe bronchopulmonary dysplasia (81, 51%), and retinopathy of prematurity (51, 32%).
Conclusion:
Oxygen saturation limits have changed over time with an overall increase in targeted SpO2. However, there remains considerable interunit variation in SpO2 policies. There is a need to achieve consensus to optimize clinical outcomes.
Key Points:
· What are the SpO2 ranges in United States' NICUs?. · There is a shift in SpO2 ranges for preterm infants in NICUs across United States.. · Variability still persists in SpO2 ranges for preterm infants in United States' NICUs..
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...