Real-World Evidence of Automated Insulin Delivery System Use
Elizabeth G Considine1, Jennifer L Sherr1
1Department of Pediatrics, Yale School of Medicine, New Haven, Connecticut, USA.
None:
Objective: Pivotal trials of automated insulin delivery (AID) closed-loop systems have demonstrated a consistent picture of glycemic benefit, supporting approval of multiple systems by the Food and Drug Administration or Conformité Européenne mark receipt. To assess how pivotal trial findings translate to commercial AID use, a systematic review of retrospective real-world studies was conducted. Methods: PubMed and EMBASE were searched for articles published after 2018 with more than five nonpregnant individuals with type 1 diabetes (T1D). Data were screened/extracted in duplicate for sample size, AID system, glycemic outcomes, and time in automation. Results: Of 80 studies identified, 20 met inclusion criteria representing 171,209 individuals. Time in target range 70-180 mg/dL (3.9-10.0 mmol/L) was the primary outcome in 65% of studies, with the majority of reports (71%) demonstrating a >10% change with AID use. Change in hemoglobin A1c (HbA1c) was reported in nine studies (range 0.1%-0.9%), whereas four reported changes in glucose management indicator (GMI) with a 0.1%-0.4% reduction noted. A decrease in HbA1c or GMI of >0.2% was achieved in two-thirds of the studies describing change in HbA1c and 80% of articles where GMI was described. Time below range <70 mg/dL (<3.9 mmol/L) was reported in 16 studies, with all but 1 study showing stable or reduced levels. Most systems had >90% time in automation. Conclusion: With larger and more diverse populations, and follow-up periods of longer duration (∼9 months vs. 3-6 months for pivotal trials), real-world retrospective analyses confirm pivotal trial findings. Given the glycemic benefits demonstrated, AID is rapidly becoming the standard of care for all people living with T1D. Individuals should be informed of these systems and differences between them, have access to and coverage for these technologies, and receive support as they integrate this mode of insulin delivery into their lives.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...