Complexity reduction of oxygen saturation variability signals in COVID-19 patients: Implications for
Madini O Alassafi1, Wajid Aziz2, Rayed AlGhamdi1
1Department of Information Technology, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah, Saudi Arabia.
Background:
Coronavirus disease 2019 (COVID-19) is a respiratory illness that leads to severe acute respiratory syndrome and various cardiorespiratory complications, contributing to morbidity and mortality. Entropy analysis has demonstrated its ability to monitor physiological states and system dynamics during health and disease. The main objective of the study is to extract information about cardiorespiratory control by conducting a complexity analysis of OSV signals using scale-based entropy measures following a two-month timeframe after recovery.
Methods:
This prospective study collected data from subjects meeting specific criteria, using a Beurer PO-80 pulse oximeter to measure oxygen saturation (SpO2) and pulse rate. Excluding individuals with a history of pulmonary/cardiovascular issues, the study analyzed 88 recordings from 44 subjects (26 men, 18 women, mean age 45.34 ± 14.40) during COVID-19 and two months post-recovery. Data preprocessing and scale-based entropy analysis were applied to assess OSV signals.
Results:
The study found a significant difference in mean OSV during illness (95.08 ± 0.15) compared to post-recovery (95.59 ± 1.03), indicating reduced cardiorespiratory dynamism during COVID-19. Multiscale entropy analyses (MSE, MPE, MFE) confirmed lower entropy values during illness across all time scales, particularly at higher scales. Notably, the maximum distinction between illness and recovery phases was seen at specific time scales and similarity criteria for each entropy measure, showing statistically significant differences.
Conclusions:
The study demonstrates that the loss of complexity in OSV signals, quantified using scale-based entropy measures, has the potential to detect malfunctioning of cardiorespiratory control in COVID-19 patients. This finding suggests that OSV signals could serve as a valuable indicator for assessing the cardiorespiratory status of COVID-19 patients and monitoring their recovery progress.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...