Related Experiment Video
Updated: May 12, 2026

Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
Published on: June 8, 2017
Mixed-Method Precooling Enhances Self-Paced 20-km Cycling Time-Trial Performance When Apparent Temperature Is >46 °C
Julian Andro P Ramos1, Kagan J Ducker1, Hugh Riddell1
1Curtin School of Allied Health, Curtin University, Perth, Australia.
Purpose:
Precooling (PreC) may only benefit performance when thermal strain experienced by an individual is sufficiently high. We explored the effect of mixed-method PreC on 20-km cycling time-trial (CTT) performance under 3 different apparent temperatures (AT).
Methods:
On separate days, 12 trained or highly trained male cyclists/triathletes completed six 20-km CTTs in 3 different ATs: hot-dry (35 °C AT), moderately hot-humid (40 °C AT), and hot-humid (46 °C AT). All trials were preceded by 30 minutes of mixed-method PreC or no PreC (control [CON]).
Results:
Faster 2.5-km-split completion times occurred in PreC compared with CON in 46 °C AT (P = .02), but not in 40 °C AT (P = .62) or 35 °C AT (P = .57). PreC did not affect rectal and body temperature during the 20-km CTT. Skin temperature was lower throughout the CTT in PreC compared with CON in 46 °C AT (P = .01), but not in 40 °C AT (P = 1.00) and 35 °C AT (P = 1.00). Heart rate had a greater rate of increase during the CTT for PreC compared with CON in 46 °C AT (P = .01), but not in 40 °C AT (P = .57) and 35 °C AT (P = 1.00). Ratings of perceived exertion (P < .001) and thermal comfort (P = .04) were lower for PreC compared with CON in 46 °C AT only, while thermal sensation was not different between PreC and CON.
Conclusion:
Mixed-method PreC should be applied prior to 20-km CTTs conducted in hot-humid conditions (≥46 °C AT). Alternatively, mixed-method PreC may be a priority in moderately hot-humid (∼40 °C AT) conditions but should not be in hot-dry (∼35 °C AT) conditions for 20-km CTT.
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Thermoregulation
Physical Methods for Controlling Microbial Growth: Temperature