Benchtop volatilomics supercharged: How machine learning based design of experiment helps optimizing untargeted
Hadi Parastar1, Philipp Weller2
1Department of Chemistry, Sharif University of Technology, P.O. Box 11155-9516, Tehran, Iran; Institute for Instrumental Analytics and Bioanalytics, Mannheim University of Applied Sciences, 68163, Mannheim, Germany.
Abstract:
Gas chromatography-ion mobility spectrometry (GC-IMS) plays a significant role in both targeted and non-targeted analyses. However, the non-linear behavior of IMS and its complex ion chemistry pose challenges for finding optimal experimental conditions using existing methodologies. To address these issues, integrating machine learning (ML) strategies offers a promising approach. In this study, we propose a hybrid strategy, combining design of experiment (DOE) and machine learning (ML) for optimizing GC-IMS conditions in non-targeted volatilomic/flavoromic analysis, with saffron volatiles as a case study. To begin, a rotatable circumscribed central composite design (CCD) is used to define five influential GC-IMS factors of sample amount, headspace temperature, incubation time, injection volume, and split ratio. Subsequently, two ML models are utilized: multiple linear regression (MLR) as a linear model and Bayesian regularized-artificial neural network (BR-ANN) as a nonlinear model. These models are employed to predict the response variables of total peak areas (PAs) and the number of detected peaks (PNs) in GC-IMS. The findings show that there is a direct correlation between the factors in GC-IMS and the PNs, suggesting that MLR is a suitable approach for building a model in this scenario. However, the PAs exhibit nonlinear behavior, suggesting that BR-ANN is better suitable to capture this complexity. Notably, Derringer's desirability function is utilized to integrate the PAs and PNs, and in this scenario, MLR demonstrates satisfactory performance in modeling the GC-IMS factors.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...