Related Experiment Video
Updated: Jul 2, 2025

Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques
Published on: March 13, 2015
Effect of a smart temperature logger on correctly storing biological disease-modifying antirheumatic drugs at home: a
Lex L Haegens1, Victor J B Huiskes2,3, Charlotte L Bekker3
1Department of Research, Sint Maartenskliniek, Nijmegen, The Netherlands l.haegens@maartenskliniek.nl.
Objectives:
Biological disease-modifying antirheumatic drugs (bDMARDs) require specific storage temperatures, but are frequently stored outside the recommended range of 2-8°C. As incorrect storage may affect therapy effectiveness and consequently lead to higher disease activity, compliance with recommended storage temperatures should be improved. eHealth interventions can provide insight into storage temperatures and alerts in case of deviations from recommended temperatures. Therefore, this study aims to assess the effect of a smart temperature logger on correctly storing bDMARDs at home by patients with rheumatic diseases.
Methods:
A pre-post study was performed in a hospital in the Netherlands. The baseline period consisted of 12 weeks of storage temperature measurement with a passive temperature logger, and the intervention period consisted of 12 weeks of storage temperature measurement with a smart temperature logger. This smart logger included a smartphone application which provided insight into storage temperatures and real-time alerts when exceeding recommended temperatures. The main outcome measure was the difference in the number of patients who stored their bDMARDs correctly between baseline and intervention. Secondary outcomes were the difference in the proportion of measurement time within 2-8°C between baseline and intervention, the distribution of measurement time among temperature categories, and the patient's acceptance measured using a questionnaire based on the Technology Acceptance Model.
Results:
In total, 48 participants (median age 55 years (IQR 47-64), 53% male) were analysed. The proportion of participants correctly storing bDMARDs increased from 18.8% (n=9) during baseline to 39.6% (n=19) during intervention (p=0.004). The median proportion of measurement time between 2-8°C improved by 6% (IQR 0-34%) (p<0.0001). Technology acceptance was scored as moderate.
Conclusions:
Temperature monitoring and real-time feedback with a smart temperature logger shows potential to improve at-home storage of bDMARDs, provided that continuous connection is realised to ensure real-time alerts and data collection.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Decreased Body Temperature
Factors Affecting Body Temperature
Factors may include:
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Increased Body Temperature
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...

