Related Experiment Video
Updated: Jul 2, 2025

Characterization of Molecular Mechanisms of In vivo UVR Induced Cataract
Published on: November 28, 2012
Background Factors Affecting the Radiation Exposure of the Lens of the Eye among Nurses in Interventional Radiology:
Tomoko Kuriyama1, Takashi Moritake2, Koichi Nakagami3
1Department of Occupational and Community Health Nursing, School of Health Sciences, University of Occupational and Environmental Health, Japan, Kitakyushu 807-8555, Japan.
Abstract:
With the International Commission on Radiological Protection's (ICRP) reduction in the radiation dose threshold for cataracts, evaluating and preventing radiation exposure to the lens of the eye among interventional radiology (IR) staff have become urgent tasks. In this study, we focused on differences in lens-equivalent dose (HT Lens) to which IR nurses in three hospitals were exposed and aimed to identify factors underlying these differences. According to analyses of time-, distance-, and shielding-related factors, the magnitude of the HT Lens dose to which IR nurses were exposed could be explained not by time or shielding but by the distance between the X-ray exposure field and the location of the IR nurse. This distance tended to be shorter in hospitals with fewer staff. The most effective means of reducing the exposure of the lenses of IR nurses' eyes to radiation is to position them at least two meters from the radiation source during angiography procedures. However, some hospitals must provide IR departments with comparatively few staff. In work environments where it is infeasible to reduce exposure by increasing distance, interventions to reduce time by managing working practices and investment in shielding equipment are also important. This study was not registered.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:08Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
Published on: May 26, 2019
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
X-ray Imaging
Focusing of Light in the Eye
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Glaucoma: Overview