Related Experiment Video
Updated: Aug 15, 2026

Use of Enzymatic Biosensors to Quantify Endogenous ATP or H2O2 in the Kidney
Published on: October 12, 2015
Two-pool model analysis of data in hemodialysis by means of programmable pocket calculator TI 59
Abstract:
Four parameters of a two-pool model are evaluated by an iterative method using the explicit solutions of the linear differential equations. For this it was presumed that the residual renal clearance is sufficiently small. Five data pairs of measured plasma concentrations ci for the time points ti (i = 0 to 4), as well as the dialyzer and residual renal clearances (KD and KR), must be given and put in the calculator. A sample run is shown for urea kinetics. The parameter estimation takes about 10 min. The program is suitable to assist in the individualization of dialysis therapy.
Related Concept Videos
Fundamental Mathematical Principles in Pharmacokinetics: Calculus and Graphs
On the other hand, integral calculus focuses on...
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Three-Compartment Open Model
Mechanistic Models: Compartment Models in Individual and Population Analysis
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications