Related Experiment Video
Updated: Jul 2, 2025

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Equation of State of Autoclaved Aerated Concrete-Oedometric Testing
Yuri S Karinski1, Vladimir R Feldgun1, David Z Yankelevsky1,2
1National Building Research Institute, Technion, Haifa 3200003, Israel.
Abstract:
This paper aims at investigating the triaxial behavior of Autoclaved Aerated Concrete (AAC) under extremely high pressures, and experimentally determine Equation of State (EOS) for several different AAC densities. Oedometric tests were carried out using a home-made high-pressure triaxial apparatus, and pressures up to ~500 MPa were applied. The complete pressure-bulk strain relationships were measured, and new findings and insights were obtained. The paper presents the testing set-up and the measurement system. The data processing method accounting for the AAC pronounced shortening during the ongoing test is described using a weighted functions procedure for the circumferential strains' calculation, with which the confining pressure was determined. The boundary conditions effects on the test results were investigated, and a new technique for specimen insulation was suggested to ensure loading without friction and the prevention of local shear failure. The experimental EOS for different AAC densities were obtained. EOS curves for different specimens with the same density demonstrated good to very good repeatability of the EOS curves over the entire pressure range. Based on the tests results and the density's span, three classes of AAC are proposed. A preliminary attempt to apply the newly obtained EOS curves has been carried out to examine the energy dissipation for three different dynamic load levels. Although this is a preliminary stage that is beyond the objective of this paper, early interesting results were observed where an optimal AAC density, for which the highest energy has been absorbed, was identified. This finding encourages inclusion of that preliminary study as a closure section. Numerical simulations of wave propagation through ACC layers of different densities, laid on rigid supporting slabs, was carried out. The minimum total impulse imparted to the rigid slab was found for the optimal AAC density that has been determined above.
More Related Videos
05:38Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
06:34Operation of a 25 KWth Calcium Looping Pilot-plant with High Oxygen Concentrations in the Calciner
Published on: October 25, 2017
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Soundness of Cement
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
Effects of Air-entrainment in Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...