Determinants of Bluetooth-Enabled Self-Measured Blood Pressure Monitoring in Federally Qualified Health Centers
Abby Hellem1, Candace Whitfield2, Maria Mansour1
1Department of Neurology, Michigan Medicine, University of Michigan, Ann Arbor, MI, USA.
Background:
In 2021, the Health Resources and Services Administration (HRSA) launched the National Hypertension Control Initiative (HTN Initiative) with the goal to enhance HTN control through Bluetooth-enabled self-measured blood pressure (BT-SMBP) monitoring and use this data to inform clinical decisions in Federally Qualified Health Centers (FQHCs) with a large proportion of their population with uncontrolled blood pressure (BP). We sought to understand the experience of Michigan-based FQHCs in implementing the HTN initiative.
Methods:
Staff from three Michigan-based FQHCs were invited to participate in semi-structured interviews from September to November 2022. Interviews were conducted in-person and were based on the Tailored Implementation in Chronic Diseases framework. Content analysis was performed by three coders.
Results:
Ten staff participated in interviews (FQHC 1: n = 6, FQHC 2: n = 1, FQHC 3: n = 3). The FQHCs differed in their stage of implementation and their approach. FQHC 1 created a large-scale, community health worker driven program, FQHC 2 created a small-scale, short term, BP device loan program, and FQHC 3 created a primarily outsourced, large-scale program through a contracted partner. Positive staff attitudes and outcome expectations, previous experience with SMBP grants, supportive clinic leadership, social support, and free BP cuff resources were identified as facilitators to implementation. Patients' high social needs, SMBP-related Technology, and insufficient workforce and staff capacity were identified as barriers.
Conclusion:
BT-SMBP among FQHC patients is promising but challenges in integrating SMBP data into clinic workflow, workforce capacity to support the high social needs of participants, and to assist in reacting to the more frequent BP data remain to be overcome.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: