Related Experiment Video
Updated: May 6, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
A Cost-Consequence Analysis Comparing Balloon-Expandable Covered Stents for the Management of Aortoiliac Occlusive
Thomas M Warburton1,2, Shannon D Thomas, Andrew Holden1,2,3
1Department of Surgery, Prince of Wales Hospital, Sydney, NSW, Australia.
Purpose:
To compare procedural and long-term costs associated with the use of Balloon-Expandable Covered Stents (BECS) in the management of Aortoiliac Occlusive Disease (AIOD).
Materials And Methods:
A cost-consequence model was developed to simulate the intra- and post-operative management of patients with AIOD from the perspective of private health-payers. The study assessed the costs of the LifeStream (BD, Franklin Lakes, New Jersey), iCAST/Advanta V12 (Getinge, Goteborg, Sweden), BeGraft Peripheral (Bentley, Hechingen, Germany), and Viabahn Balloon Expandable (VBX) (W.L. Gore, Flagstaff, Arizona) BECS devices. Device costs were identified from the Australian Prosthesis List, whereas clinical outcomes of BECS were estimated from a systematic review of the literature. Costs were calculated over 24 and 36 month time horizons and reported in US dollars.
Results:
Long-term, per-patient cost of each device at 24 and 36 months was $6255/$6776 for the LifeStream; $6631/$6870 for the iCAST/Advanta V12; $4807 (data available to 24 months) for the BeGraft Peripheral; and $4839/$5078 for the Viabahn VBX, respectively. Most of the cost difference was attributed to the number of stents required per treated limb and frequency of clinically-driven target lesion revascularization events.
Conclusions:
Best-available clinical evidence and economic modeling demonstrates that the BeGraft Peripheral and Viabahn VBX were of similar cost and the least costly options at 24 months, whereas at 36 months, the lowest cost BECS option for the treatment of AIOD was the Viabahn VBX.Clinical ImpactThis analysis supports economically informed decision-making for health-payers managing systems that care for patients with AIOD. Stent length and avoiding reintervention were identified as key areas of cost-saving for future BECS development.
More Related Videos
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Aneurysm III: Interprofessional Care