Related Experiment Video
Updated: May 3, 2026

Mesenteric Artery Contraction and Relaxation Studies Using Automated Wire Myography
Published on: September 22, 2011
Cervical artery tortuosity-a reliable semi-automated magnetic resonance-based method
Lukas Mayer-Suess1, Tamara Peball1, Sergiy Pereverzyev2,3
1Department of Neurology, Medical University of Innsbruck, Innsbruck, Austria.
Background:
Assessments of subclinical connective tissue disorders depend on complex approaches, emphasizing the need for more accessible methods applicable to clinical routine. Therefore, we aimed to establish a reliable approach assessing cervical vessel tortuosity, which is known to be associated with such disorders.
Methods:
Magnetic resonance angiography (MRA) images of ReSect study participants [single-center prospective cohort of spontaneous cervical artery dissection (sCeAD) patients] were used. Each patient underwent the same magnetic resonance imaging (MRI) protocol. The segmentation procedure was done using MATrix LABoratory 9.4 [up-sampling of raw MRA images, distance metric (DM) calculation], ITK-SNAP [region of interest (ROI) determination, vessel segmentation] and Vascular Modelling ToolKit (centerline determination). To assess inter-user variability and validity, we (I) had two blinded independent users segment all arteries and we (II) compared the results of our method to visual appraisal of vessel tortuosity done by two blinded expert neuro-radiologists.
Results:
A total of 526 extracranial cervical arteries were available for analysis. The inter-user variability of our method users was below 0.5% throughout. Overall, our method outperformed the visual tortuosity appraisal, as the visual grading underestimated the DM in 38.8% subjects when tasked to assess overall cervical artery tortuosity (both vertebral and internal carotid arteries) and in 16.6% and 33.3% respectively if tasked to grade anterior or posterior circulation separately.
Conclusions:
We present a reliable method to assess cervical artery tortuosity derived from MRA images applicable in clinical routine and future research investigating the potential correlation of sCeAD and connective tissue disorder.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System IV: CMRI