Related Experiment Video
Updated: Jul 2, 2025

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Cause of Extensor Pollicis Longus Ruptures After Distal Radius Fracture Fixation Using a Volar Plate
Charlotte L E Laane1,2, Anjuli L Dijkmans1, Chelsea J Messinger1,3,4
1Division of Hand Surgery, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, USA.
Background:
This research sought to analyze a cohort of patients with extensor pollicis longus (EPL) ruptures after volar locked plating of a distal radius fracture (DRF) to characterize the incidence of ruptures that are unlikely to be related to dorsal screw prominence.
Methods:
This is a retrospective, observational, descriptive cohort study of adults with operative fixation of a closed DRF and an EPL rupture between 2002 and 2022. Eighteen patients with operative fixation using a volar plate of a closed DRF had an EPL rupture. The cohort consisted of 66% women with an average age of 57.5 years. Median follow-up was 14.5 months.
Results:
The incidence of EPL rupture was 0.4% (18/4768). The average time from DRF and DRF fixation to EPL rupture was 3.7 and 3.4 months, respectively. Based on the operative record, in 2 of the 18 patients (11%), the rupture was directly attributable to prominent hardware; however, in 4 of the 18 patients (22%), the rupture was not related to prominent hardware, and the cause was indeterminate in 12 patients (67%). Radiologic analysis of those in the indeterminate group demonstrated that 5 of the 12 patients had screws that had a high probability of being prominent.
Conclusions:
The incidence of EPL rupture after volar plating of DRF is between 0% and 1% and usually occurs about 3 months after fixation. Approximately 50% of EPL ruptures are attributable to prominent dorsal screws. Although screw prominence is an important cause of EPL rupture, it is not the sole cause of rupture.
More Related Videos
08:27Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
Published on: May 23, 2025
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Ulna
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...