Occupational radiation doses for orthopaedic theatre staff using fluoroscopy are well below safety limits. The study found mean annual radiation exposure significantly lower than the 20mSv annual reference threshold.
Area of Science:
- Medical Physics
- Occupational Health
- Orthopaedic Surgery
Background:
- Fluoroscopy use in orthopaedic surgery poses a risk of radiation-induced carcinoma for theatre staff.
- Accurate assessment of occupational radiation doses (ORD) is crucial for staff safety.
- Established reference standards provide benchmarks for acceptable radiation exposure levels.
Purpose of the Study:
- To quantify occupational radiation doses (ORD) for orthopaedic theatre personnel during fluoroscopy-guided procedures.
- To compare calculated ORD with established international reference standards.
- To identify variations in radiation exposure among different theatre staff roles.
Main Methods:
- Dose Area Products (DAP) were recorded during 50 common orthopaedic surgeries across two hospitals.
- Occupational radiation doses (ORD) for four distinct theatre personnel roles were simulated.
- Statistical analysis was performed on the collected and simulated ORD data.
Main Results:
- The calculated mean annual occupational radiation dose was 0.977 mSv.
- All recorded dosages were significantly below the annual reference threshold of 20 mSv.
- Orthopaedic surgeons received the highest proportion of the total ORD (88.89%), while anaesthetists received the least (77.78%).
Conclusions:
- Occupational radiation doses for orthopaedic theatre staff during fluoroscopy-guided surgeries are within safe limits.
- The study highlights the need for radiation safety protocols tailored to specific roles within the operating theatre.
- Findings support the continued use of fluoroscopy in orthopaedic procedures with appropriate protective measures.
More Related Videos
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022