Universal Fetal Echocardiography for Pregestational Diabetes Mellitus: A Cost-Effectiveness Analysis
Leah M Savitsky1, Caitlin Hamilton, Mary Sterrett
1Department of Obstetrics and Gynecology, University of Washington, and the Department of Maternal-Fetal Medicine, Providence Swedish Hospital, Seattle, Washington; and the Department of Maternal-Fetal Medicine, Kaiser San Diego, San Diego, California.
Objective:
To evaluate the cost effectiveness of universal fetal echocardiogram for patients with pregestational diabetes mellitus by first-trimester hemoglobin A 1c (Hb A 1c ) level.
Methods:
We developed a cost-effectiveness model comparing two strategies of screening for critical fetal congenital heart disease among patients with diabetes: universal fetal echocardiogram and fetal echocardiogram only after abnormal findings on detailed anatomy ultrasonogram. We excluded ventricular septal defect, atrial septal defects, and bicuspid aortic valve from the definition of critical fetal congenital heart disease. Probabilities and costs were derived from the literature. We used individual models to evaluate different scenarios: first-trimester Hb A 1c lower than 6.5%, Hb A 1c 6.5-9.0%, and Hb A 1c higher than 9.0%. Primary outcomes included fetal death, neonatal death, and false-positive and false-negative results. A cost-effectiveness threshold was set at $100,000 per quality-adjusted life-year. Univariable sensitivity analyses were performed to investigate the drivers of the model.
Results:
Universal fetal echocardiogram is not cost effective except for when first-trimester Hb A 1c level is higher than 9.0% (incremental cost-effectiveness ratio $638,100, $223,693, and $67,697 for Hb A 1c lower than 6.5%, 6.5-9.0%, and higher than 9.0%, respectively). The models are sensitive to changes in the probability of congenital heart disease at a given Hb A 1c level, as well as the cost of neonatal transfer to a higher level of care. Universal fetal echocardiogram became both cost saving and more effective when the probability of congenital heart disease reached 14.48% (15.4 times the baseline risk). In the Monte Carlo simulation, universal fetal echocardiogram is cost effective in 22.7%, 48.6%, and 62.3% of scenarios for each of the three models, respectively.
Conclusion:
For pregnant patients with first-trimester Hb A 1c levels lower than 6.5%, universal fetal echocardiogram was not cost effective, whereas, for those with first-trimester Hb A 1c levels higher than 9.0%, universal fetal echocardiogram was cost effective. For those with intermediate Hb A 1c levels, universal fetal echocardiogram was cost effective in about 50% of cases; therefore, clinical judgment based on individual patient values, willingness to pay to detect congenital heart disease, and resource availability needs to be considered.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Diabetes Mellitus: Type 2 and Gestational
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):