Related Experiment Video
Updated: Jul 1, 2025

Sample Preparation in Quartz Crystal Microbalance Measurements of Protein Adsorption and Polymer Mechanics
Published on: January 22, 2020
An electrochemical quartz crystal microbalance (EQCM) based on microelectrode arrays allows to distinguish between
Michael Biermann1, Christian Leppin1, Arne Langhoff1
1Institute of Physical Chemistry, Clausthal University of Technology, Arnold-Sommerfeld-Straße 4, D 38678 Clausthal-Zellerfeld, Germany. christian.leppin@tu-clausthal.de.
Abstract:
Using a precise electrochemical quartz crystal microbalance (EQCM), it was shown that electrogravimetry can be carried out with microelectrode arrays (MEAs). MEAs were prepared on the resonator surface by coating it with a thin polymer layer containing holes, where the holes constitute the microelectrodes. The preparation procedures, their benefits, and their limitations are discussed. Microelectrode-based electrogravimetry is challenging because the reduced active area reduces the QCM signal. It is still feasible. This work is limited to linear voltage ramps (as opposed to steps). The processes chosen for demonstration were the electrodeposition/stripping of copper and the redox cycling of methyl viologen dichloride (MVC). The current trace often showed microelectrodic behavior, depending on the sweep rate. For the case of copper deposition, the mass transfer rate was proportional to the electric current. For the case of MVC, the electric current showed a plateau at the ends of the current-voltage diagram, but the mass transfer rate did not change. The difference can be explained by adsorption and desorption going into saturation at the two ends of the voltage range. Based on whether or not a microelectrodic gravimetric signal is seen, it can be stated whether the mass transfer is closely linked to the current. Further advantages of the microelectrode-based EQCM are an improved access to fast processes, reduced effects of double layer recharging, and the possibility to work at a low electrolyte support.
More Related Videos
07:11Dissipative Microgravimetry to Study the Binding Dynamics of the Phospholipid Binding Protein Annexin A2 to Solid-supported Lipid Bilayers Using a Quartz Resonator
Published on: November 1, 2018
05:03Precise Electrochemical Sizing of Individual Electro-Inactive Particles
Published on: August 4, 2023
Related Concept Videos
Electrogravimetric Analysis: Overview
To test the completeness of the...
Electrodeposition
Electrodeposition can...
Interfacial Electrochemical Methods: Overview
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation