A nasal airflow oscillation device targeting nasal congestion: a preliminary report
1Department of Otolaryngology - Head and Neck Surgery, Manukau Superclinic, 901 Great South Road, Manukau City Centre, Auckland, 2104, New Zealand. jimbartley56@gmail.com.
Purpose:
Upper respiratory tract complaints are common in the general population. A safe, non-pharmacologic treatment would be an attractive option for many patients either as an alternative to existing therapies, or as a complementary therapy. This study assessed the acceptability, safety and possible efficacy of a nasal airflow oscillation device in a group of people suffering chronic nasal congestion.
Methods:
Subjects with a known history of nasal congestion, but without fixed anatomical obstruction, participated in a prospective clinical study. Efficacy was assessed using peak nasal inspiratory flow (NPIF) and a 10-point visual analogue scale (VAS) administered before and after the oscillation device had been worn for twenty minutes.
Results:
Twenty-one subjects (mean age 37 years; 43% female) were enrolled in the study. After treatment with the small nasal airflow oscillation device for twenty minutes, average NPIF increased significantly from 84.8 L/minute to 99.0 L/minute (p < 0.05). There was a corresponding significant reduction in the VAS score for nasal congestion (p < 0.05). Similar significant improvements were also seen for the immediate sensation of nasal drainage, sinonasal pressure and overall sinonasal symptoms (p < 0.05). There was no change in the sense of smell (p = 0.37). Subjects rated ease of use highly; average = 9.1 (Range 7-10).
Conclusion:
Treatment of nasal congestion with the nasal airflow oscillation device was found to result in significant improvement in NPIF after twenty minutes of use. Initial patient-reported outcomes improved significantly, and the treatment was safe and highly acceptable.
Trial Registration:
Public clinical trial registration: Universal Trial Number (U1111-1259-0704). Australian New Zealand clinical trials registration: ACTRN12623001307695.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...