Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Development of the Limb Synovial Joints01:07

Development of the Limb Synovial Joints

1.4K
Joints form during embryonic development in conjunction with the formation and growth of the associated bones. The embryonic tissue that gives rise to all bones, cartilage, and connective tissues of the body is called mesenchyme.
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...
1.4K
Knee Joint01:23

Knee Joint

1.8K
The knee joint is the most complicated joint in the body. It consists of three articulations– two tibiofemoral and one patellofemoral. As is characteristic of synovial joints, the knee joint has a thin articular capsule that partially surrounds this joint cavity. Additionally, several ligaments, muscles, and cartilaginous structures support the movement of the knee.
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
1.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reply to Letter to the Editor on "Optimizing Postoperative Pain Management in Total Knee Arthroplasty With Preoperative Methadone: A Prospective Randomized Study".

The Journal of arthroplastyĀ·2026
Same author

Classification and Outcomes of 214 Periprosthetic Patellar Fractures in Primary Total Knee Arthroplasty.

The Journal of arthroplastyĀ·2026
Same author

A Contemporary Comparison of Modern Cementless to Cemented Femoral Stems for the Treatment of Femoral Neck Fractures.

The Journal of arthroplastyĀ·2026
Same author

Time to Reimplantation: Waiting Longer May Increase the Risk of Subsequent Failure.

The Journal of arthroplastyĀ·2026
Same author

Comparative Outcomes of Modular Versus Monoblock Fluted Tapered Stems in Revision Total Hip Arthroplasty: An American Joint Replacement Registry Analysis.

The Journal of arthroplastyĀ·2026
Same author

Cementless Total Knee Arthroplasty in the Morbidly Obese Patient Using a Highly Porous Tibial Baseplate: Minimum 10-Year Follow-Up.

The Journal of arthroplastyĀ·2026

Related Experiment Video

Updated: Jul 1, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
07:45

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report

Published on: August 4, 2022

3.4K

Modular Revision System for Complex Hip Revisions: A Case Series.

Daniel Hameed1, Brittany Oster2, Bryan D Springer3

  • 11LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland.

Surgical Technology International
|March 5, 2024
PubMed
Summary

Revision total hip arthroplasty (THA) presents challenges, particularly with femoral bone defects. A modified modular fluted tapered system, now featuring shorter stems, offers a reliable solution for complex hip revision cases.

More Related Videos

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
10:35

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction

Published on: December 3, 2017

11.2K
The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
09:51

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve

Published on: September 7, 2022

2.6K

Related Experiment Videos

Last Updated: Jul 1, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
07:45

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report

Published on: August 4, 2022

3.4K
Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
10:35

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction

Published on: December 3, 2017

11.2K
The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
09:51

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve

Published on: September 7, 2022

2.6K

Area of Science:

  • Orthopedic Surgery
  • Biomedical Engineering

Background:

  • Revision total hip arthroplasty (THA) is complex, often complicated by femoral bone defects from prior surgeries or aseptic loosening.
  • A modular fluted tapered system, established in 2003 and used in over 180,000 procedures, aids surgeons in managing these challenging cases.

Purpose of the Study:

  • To evaluate the efficacy and advantages of a newly introduced short-stem modification (115mm) of a modular fluted tapered hip revision system.
  • To demonstrate the versatility of the short-stem components in addressing diverse femoral bone defect scenarios during revision THA.

Main Methods:

  • A case series of six distinct patients undergoing revision total hip arthroplasty.
  • Utilized a modified modular fluted tapered system with newly available shorter stem components (115mm).
  • Documented the application of the short-stem system across various complex revision scenarios.

Main Results:

  • The case series successfully demonstrated the application of the new 115mm short-stem components in revision THA.
  • The modified system proved effective in managing unique patient challenges and diverse femoral bone defects.
  • The shorter stem components provided a viable option for complex hip revision procedures.

Conclusions:

  • The modified modular fluted tapered system, with its new short-stem option, is a valuable tool for addressing complex revision total hip arthroplasty cases.
  • This modification expands the applicability of the system, offering solutions for a wider range of femoral bone defect presentations.
  • The presented cases highlight the reliability and effectiveness of the short-stem components in challenging revision scenarios.