Related Experiment Video
Updated: Jun 22, 2026

Microfluidic Imaging Flow Cytometry by Asymmetric-detection Time-stretch Optical Microscopy ATOM
Published on: June 28, 2017
Miniaturized time-correlated single-photon counting module for time-of-flight non-line-of-sight imaging applications
Jie Wu1,2, Chao Yu1,2, Jian-Wei Zeng1,2
1Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China.
Abstract:
Single-photon time-of-flight (TOF) non-line-of-sight (NLOS) imaging enables the high-resolution reconstruction of objects outside the field of view. The compactness of TOF NLOS imaging systems, entailing the miniaturization of key components within such systems, is crucial for practical applications. Here, we present a miniaturized four-channel time-correlated single-photon counting module dedicated to TOF NLOS imaging applications. The module achieves excellent performance with a 10 ps bin size and 27.4 ps minimum root-mean-square time resolution. We present the results of the TOF NLOS imaging experiment using an InGaAs/InP single-photon detector and the time-correlated single-photon counting module and show that a 6.3 cm lateral resolution and 2.3 cm depth resolution can be achieved under the conditions of 5 m imaging distance and 1 ms pixel dwell time.