Related Experiment Video
Updated: Jul 1, 2025

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Associations between ultra-distal forearm bone mineral density and incident fracture in women
Kara L Holloway-Kew1, Amelia G Betson2, Kara B Anderson2
1Deakin University, Institute for Mental and Physical Health and Clinical Translation - IMPACT, Geelong, Australia. k.holloway@deakin.edu.au.
Abstract:
Bone mineral density measured at the ultra-distal forearm site was associated with any fracture, as well as distal radius fracture in women from a longitudinal cohort study.
Purpose:
Femoral neck (BMDhip) and lumbar spine (BMDspine) bone mineral density (BMD) are routinely used to assess fracture risk. More data are needed to understand how ultra-distal forearm BMD (BMDUDforearm) may assist fracture prediction.
Methods:
Using a Lunar DPX-L, Geelong Osteoporosis Study women (n = 1026), aged 40-90 years, had BMD measured. Incident low-trauma fractures were radiologically verified. Using Cox proportional hazard models, hazard ratios (HR) were calculated for BMDUDforearm as a continuous variable (expressed as a one-unit decrease in T-score) and a categorical variable (normal/osteopenia/osteoporosis). Areas under receiver operating characteristics (AUROC) curves were calculated. Analyses were conducted for any fracture and distal radius fractures.
Results:
During 14,270 person-years of follow-up, there were 318 fractures (85 distal radius). In adjusted models, continuous BMDUDforearm was associated with any (HR 1.26;95%CI 1.15-1.39) and distal radius fractures (HR 1.59;95%CI 1.38-1.83). AUROCs for continuous BMDUDforearm, 33% forearm(BMD33%forearm), BMDhip, BMDspine, and FRAX without BMD were similar for any fracture (p > 0.05). For distal radius fracture, the AUROC for BMDUDforearm was higher than other sites and FRAX (p < 0.05). In adjusted models, those with osteoporosis had a higher likelihood of any fracture (HR 2.12; 95%CI 1.50-2.98). For distal radius fractures, both osteopenia and osteoporosis had a higher risk (HR 4.31; 95%CI 2.59-7.15 and 4.81; 95%CI 2.70-8.58). AUROCs for any fracture were similar for categorical BMD at all sites but lower for FRAX (p < 0.05). For distal radius fractures, the AUROC for BMDUDforearm, was higher than other sites and FRAX (p < 0.05).
Conclusion:
Ultra-distal forearm BMD may aid risk assessments for any distal radius fractures.
Related Concept Videos
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Essential Minerals for Bone Health
Calcium and Phosphorus
Calcium is a critical component of bones, especially in the form of calcium phosphate and calcium carbonate. Since the body cannot make calcium, it must be obtained from the diet. However, calcium cannot be absorbed from the small intestine without...
Role of Vitamins in Maintaining Bone Health
Vitamin A
Vitamin A is involved in the process of bone remodeling. Retinoic acid, the active metabolite of Vitamin A, has nuclear receptors in osteoblasts and osteoclasts, which are involved in bone remodeling.
Vitamin B12
Vitamin B12 acts as a cofactor during the formation of osteoblast-related proteins, such as osteocalcin. Vitamin B12 plays a role...
Bone Remodeling

