Related Experiment Video
Updated: Jul 1, 2025

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
Development and validation of the effective CNR analysis method for evaluating the contrast resolution of CT images
Kengo Igarashi1, Kuniharu Imai2, Shigeru Matsushima2
1Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, 1-1-20, Daiko-Minami, Higashi-ku, Nagoya, Aichi, 461-8673, Japan. igarashi.kengo.a5@s.mail.nagoya-u.ac.jp.
Abstract:
Contrast resolution is an important index for evaluating the signal detectability of computed tomographic (CT) images. Recently, various noise reduction algorithms, such as iterative reconstruction (IR) and deep learning reconstruction (DLR), have been proposed to reduce the image noise in CT images. However, these algorithms cause changes in the image noise texture and blurred image signals in CT images. Furthermore, the contrast-to-noise ratio (CNR) cannot be accurately evaluated in CT images reconstructed using noise reduction methods. Therefore, in this study, we devised a new method, namely, "effective CNR analysis," for evaluating the contrast resolution of CT images. We verified whether the proposed algorithm could evaluate the effective contrast resolution based on the signal detectability of CT images. The findings showed that the effective CNR values obtained using the proposed method correlated well with the subjective visual impressions of CT images. To investigate whether signal detectability was appropriately evaluated using effective CNR analysis, the conventional CNR analysis method was compared with the proposed method. The CNRs of the IR and DLR images calculated using conventional CNR analysis were 13.2 and 10.7, respectively. By contrast, those calculated using the effective CNR analysis were estimated to be 0.7 and 1.1, respectively. Considering that the signal visibility of DLR images was superior to that of IR images, our proposed effective CNR analysis was shown to be appropriate for evaluating the contrast resolution of CT images.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...