Related Experiment Video
Updated: Jul 1, 2025

A Method for Systematic Electrochemical and Electrophysiological Evaluation of Neural Recording Electrodes
Published on: March 3, 2014
Effect of reference electrode on intracardiac electrograms: Close indifferent electrode vs Wilson central terminal
Tasuku Yamamoto1, Masateru Takigawa2, Takatoshi Shigeta1
1Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Tokyo, Japan.
Background:
Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging.
Objective:
The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms.
Methods:
Sinus node activation was mapped in patients undergoing catheter ablation by a multielectrode array with a close indifferent electrode (CIE) embedded in the distal end of the catheter shaft. An equal number of points was sequentially acquired at each site with use of CIE as a reference first and subsequently with WCT. Uni-EGMs, bipolar EGMs, and the earliest activation area (defined as the area activated in the first 10 ms of the beat) were compared between CIE- and WCT-based activation maps.
Results:
Seventeen patients (61 ± 18 years; 76% male) were studied. Uni-EGM voltages acquired with CIE were significantly larger than (n = 11) or comparable to (n = 4) those acquired with WCT. When points from the entire cohort were analyzed altogether, unipolar voltages and their maximum negative dV/dT and bipolar voltages recorded with CIE were significantly larger than those recorded with WCT (2.36 [1.42-3.79] mV vs 1.96 [1.25-3.03] mV, P < .0001; 0.40 [0.18-0.77] mV/s vs 0.35 [0.15-0.71] mV/s, P < .0001; and 1.46 [0.66-2.81] mV vs 1.33 [0.54-2.64] mV, P < .0001, respectively). The earliest activation area was significantly smaller in CIE-based activation maps than in WCT-based ones (0.3 [0.7-1.4] cm2 vs 0.6 [1.0-1.8] cm2, P = .01).
Conclusion:
CIE-based maps were associated with an approximately 20% increase in unipolar voltage and may highlight the origin of a focal activation more clearly than WCT-based ones.
More Related Videos
06:40Impact of Intracardiac Neurons on Cardiac Electrophysiology and Arrhythmogenesis in an Ex Vivo Langendorff System
Published on: May 22, 2018
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Bode Plots Construction