Peripheral defocus of monofocal intraocular lenses
Ramya Natarajan1, Bianca Maceo Heilman, Arthur Ho
1From the Ophthalmic Biophysics Laboratory, L V Prasad Eye Institute, Hyderabad, Telangana, India (Natarajan, Singh, Mohamed, Vadavalli); Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida (Heilman, Ruggeri, Parel, Manns); Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida (Heilman, Ruggeri, Parel, Manns); Brien Holden Vision Institute Limited, Sydney, New South Wales, Australia; School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia (Ho); Cataract & Refractive surgery services, L V Prasad Eye Institute, Hyderabad, Telangana, India (Singh, Reddy, Vadavalli); The Shantilal Shanghvi Cornea Institute, L V Prasad Eye Institute, Hyderabad, Telangana, India (Vadavalli).
Purpose:
To quantify the angular dependence of monofocal intraocular lens (IOL) power.
Setting:
Ophthalmic Biophysics Laboratory, Kallam Anji Reddy campus, L V Prasad Eye Institute, Hyderabad, India.
Design:
Laboratory study.
Methods:
Experiments were performed on IOLs from 2 different manufacturers (APPALENS 207, Appasamy Associates and SN60WF, Alcon Laboratories, Inc.). IOL powers ranged from 17 to 25 diopters (D). The IOLs were mounted in a fluid-filled chamber, and the on-axis and off-axis powers were measured using a laser ray tracing system over the central 3 mm zone with delivery angles ranging from -30 to +30 degrees in 5-degree increments. The position of the best focus was calculated for each IOL at each angle. The angular dependence of IOL power was compared with theoretical predictions.
Results:
Peripheral defocus increased significantly with increasing incidence angle and power. The peripheral defocus at ±30 degrees increased from 5.8 to 8.5 D when the power increased from 17.5 to 24.5 D for APPALENS 207 and from 4.9 to 7.4 D when the power increased from 17 to 25 D for SN60WF. The mean difference between the measured and theoretical tangential power at ±30 degrees was 0.50 ± 0.16 D for the APPALENS 207 and -0.40 ± 0.10 D for the SN60WF, independent of IOL power.
Conclusions:
IOLs introduce a significant amount of peripheral defocus which varies significantly with IOL power and design. Given that peripheral defocus is related to lens power, replacement of the crystalline lens (approximately 24 D) with an IOL will produce a significant difference in peripheral defocus profile after surgery.
More Related Videos
11:29Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Focusing of Light in the Eye
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Confocal Fluorescence Microscopy
Angle Closure Glaucoma: Treatment
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...