X-Ray Computed Tomography Instrument Performance Evaluation, Part III: Sensitivity to Detector Geometry and Rotation
Prashanth Jaganmohan1,2, Bala Muralikrishnan1, Meghan Shilling1
1Sensor Science Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
Abstract:
With steadily increasing use in dimensional metrology applications, especially for delicate parts and those with complex internal features, X-ray computed tomography (XCT) has transitioned from a medical imaging tool to an inspection tool in industrial metrology. This has resulted in the demand for standardized test procedures and performance evaluation standards to enable reliable comparison of different instruments and support claims of metrological traceability. To meet these emerging needs, the American Society of Mechanical Engineers (ASME) recently released the B89.4.23 standard for performance evaluation of XCT systems. There are also ongoing efforts within the International Organization for Standardization (ISO) to develop performance evaluation documentary standards that would allow users to compare measurement performance across instruments and verify manufacturer's performance specifications. Designing these documentary standards involves identifying test procedures that are sensitive to known error sources. This paper, which is the third in a series, focuses on geometric errors associated with the detector and rotation stage of XCT instruments. Part I recommended positions of spheres in the measurement volume such that the sphere center-to-center distance error and sphere form errors are sensitive to the detector geometry errors. Part II reported similar studies on the errors associated with the rotation stage. The studies in Parts I and II only considered one position of the rotation stage and detector; i.e., the studies were conducted for a fixed measurement volume. Here, we extend these studies to include varying positions of the detector and rotation stage to study the effect of magnification. We report on the optimal placement of the stage and detector that can bring about the highest sensitivity to each error.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...