Background:
Substance use is an important public health problem and increasing all over the world. Different methods have been defined for drug abuse testing in medical laboratories. We aimed to compare two urine drug screening methods with liquid chromatography-tandem mass spectrometry (LC-MS/MS).
Methods:
A total of 102 patients' urine samples were analyzed by test dip card and EMIT (enzyme multiplied im-munoassay technique). Randomly selected samples (n = 51; 50%) were also analyzed by LC-MS/MS as the reference method.
Results:
The drug results of all patients analyzed with the test card and EMIT were compatible. Nine of 51 samples (18%) were negative according to all methods. The sensitivity and specificity percentages of AMP, COC, MDMA, OPI/MOP, and THC using test card were 70/96, 100/100, 47/100, 50/100, and 80/85, respectively. Similarly, the sensitivity and specificity percentages of AMP, COC, MDMA, OPI/MOP, and THC using EMIT were 76/97, 100/100, 57/100, 56/100, and 76/91, respectively.
Conclusions:
The performances of two immunochemical methods were similar for AMP, BZO, COC, MDMA, OPI/MOP, and THC whereas lower than LCMS/MS for AMP, MDMA, OPI/MOP, and THC. A sample that is positive according to any immunochemical method should be confirmed by definitive techniques such as LC-MS/MS.
Related Concept Videos
Drug Elimination by Renal Route: Tubular Reabsorption
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Drug Excretion: Tubular Reabsorption
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Drug Concentrations: Measurements
Plasma...