Related Experiment Video
Updated: May 11, 2026

Three-dimensional Optical-resolution Photoacoustic Microscopy
Published on: May 3, 2011
Abstract:
Longitudinal detection of hemodynamic changes based on wearable devices is imperative for monitoring human healthcare. Photoacoustic effect is extremely sensitive to variations in hemoglobin. Therefore, wearable photoacoustic devices are apt to monitor human healthcare via the observation of hemodynamics. However, the bulky system and difficulties in miniaturizing and optimizing the imaging interface restrict the development of wearable photoacoustic devices for human use. In this study, we developed a wearable photoacoustic watch with a fully integrated system in a backpack that has a size of 450 mm × 300 mm × 200 mm and an affordable weight of 7 kg for an adult to wear. The watch has a size of 43 mm × 30 mm × 24 mm, weighs 40 g, and features a lateral resolution of 8.7 µm, a field of view (FOV) of 3 mm in diameter, and a motorized adjustable focus for optimizing the imaging plane for different individuals. We recruited volunteers to wear the watch and the backpack and performed in vivo imaging of the vasculatures inside human wrists under the conditions of walking and human cuff occlusion to observe hemodynamic variations during different physiological states. The results suggest that the focus shifting capability of the watch makes it suitable for different individuals, and the compact and stable design of the entire system allows free movements of humans.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
09:43Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging
Published on: October 16, 2017
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Electronic Distance Measuring Instruments