Related Experiment Video
Updated: Jun 29, 2026

High Throughput, Real-time, Dual-readout Testing of Intracellular Antimicrobial Activity and Eukaryotic Cell Cytotoxicity
Published on: November 16, 2016
Development and Validation of a New Reversed Phase HPLC Method for the Quantitation of Azithromycin and Rifampicin in
Foram Patel1, Rajendra Kotadiya1, Rashmin Patel1
1Department of Quality Assurance, Ramanbhai Patel College of Pharmacy, Charotar University of Science and Technology (CHARUSAT), CHARUSAT Campus, Changa, Dist-Anand, Gujarat 388421, India.
Abstract:
This research aimed to develop a new method for simultaneously estimating the presence of azithromycin (AZT) and rifampicin (RIF) in a capsule formulation using reverse-phase high-performance liquid chromatography. The developed method utilized a Gemini column with a 60:40% v/v acetonitrile and potassium dihydrogen phosphate mobile phase, a flow rate of 1 mL/min, and an injection volume of 20 μL. The detection wavelengths of 210 and 254 nm for AZT and RIF, respectively, were used. Validation ensures specificity with a peak purity index > 0.99999 for AZT and >0.99995 for RIF, affirming unambiguous analyte detection. The system suitability test, within acceptable limits, validates method reliability. Linearity calibration curves (R2 = 0.998) cover a 25-150% target concentration range. Accuracy studies employing the standard addition method yield recovery values between 96.6 and 103.9% for both drugs, confirming method accuracy. Precision studies reveal % relative standard deviation values consistently below 2%, highlighting reproducibility. Robustness testing supports method reliability under varying conditions. Application to a pharmaceutical capsule formulation demonstrates the method's practicality, accurately quantifying AZT (98.30%) and RIF (99.37%). This study provides a validated analytical approach for simultaneous quantification in commercial pharmaceutical products containing both drugs, enhancing pharmaceutical quality control for critical antibiotics in complex formulations.
More Related Videos
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation