Related Experiment Video
Updated: Jun 30, 2025

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
RPCA-based techniques for pattern extraction, hotspot identification and signal correction using data from a dense
Martin Bogaert1, Christian Mouritzen2, Matthew S Johnson3
1Department of Civil and Environmental Engineering, Imperial College London, United Kingdom.
Abstract:
High-density low-cost air quality sensor networks are a promising technology to monitor air quality at high temporal and spatial resolution. However the collected data is high-dimensional and it is not always clear how to best leverage this information, particularly given the lower data quality coming from the sensors. Here we report on the use of robust Principal Component Analysis (RPCA) using nitrogen dioxide data obtained from a recently deployed dense network of 225 air pollution monitoring nodes based on low-cost sensors in the Borough of Camden in London. RPCA addresses the brittleness of singular value decomposition towards outliers by using a decomposition of the data into low-rank and sparse contributions, with the latter containing outliers. The modal decomposition enabled by RPCA identifies major periodic patterns including spatial and temporal bias, dominant spatial variance, and north-south bias. The five most descriptive components capture 98 % of the data's variance, achieving a compression by a factor of 1500. We present a new technique that uses the sparse part of the data to identify hotspots. The data indicates that at the locations of the top 15 % most susceptible nodes in the network, the model identifies 23 % more hotspots than in all other locations combined. Moreover, the median hotspot event at these at-risk locations exceeds the mean NO2concentration by 33μg/m3. We show the potential of RPCA for signal correction; it corrects random errors yielding a reference signal with R2>0.8. Moreover, RPCA successfully reconstructs missing data from a sensor with R2=0.72 from the rest of the sensor network, an improvement upon PCA of around 50 %, allowing air quality estimations even if a sensor is out of use temporarily.
More Related Videos
11:54Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019