Related Experiment Video
Updated: Jun 30, 2025

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Effects of E-Cigarette Liquid Ratios on the Gravimetric Filter Correction Factors and Real-Time Measurements
Austin Close1, Jane Blackerby1, Heather Tunnell2
1Department of Public Health, Brody School of Medicine, East Carolina University, Greenville, NC 27834, USA.
Abstract:
Electronic cigarettes (ECIGs) generate high concentrations of particulate matter (PM), impacting the air quality inhaled by humans through secondhand exposure. ECIG liquids are available commercially and some users create their own "do-it-yourself" liquids, and these liquids often vary in the amounts of their chemical ingredients, including propylene glycol (PG) and vegetable glycerin (VG). Previous studies have quantified PM concentrations in ECIG aerosol generated from liquids containing different PG/VG ratios. However, the effects of these ratios on aerosol instrument filter correction factors needed to measure PM concentrations accurately have not been assessed. Thus, ECIG aerosol filter correction factors for multiple aerosol instruments (SMPS + APS, MiniWRAS, pDR, and SidePak) were determined for five different PG/VG ratios 1) 0PG/100VG, 2) 15PG/85VG, 3) 50PG/50VG, 4) 72PG/28VG, and 5) 90PG/10VG and two different PM sizes, PM1 (1 μm and smaller) and PM2.5 (2.5 μm and smaller). ECIG aerosols were generated inside a controlled exposure chamber using a diaphragm pump and a refillable ECIG device for all the ratios. In addition, the aerosol size distribution and mass median diameter were measured for all five ECIG ratios. PM2.5 correction factors (5-7.6) for ratios 1, 2, 3, and 4 were similar for the SMPS + APS combined data, and ratios 1, 2, 3 were similar for the MiniWRAS (~2), pDR (~0.5), and SidePak (~0.24). These data suggest different correction factors may need to be developed for aerosol generated from ECIGs with high PG content. The higher correction factor values for the 90PG/10VG ratio may have resulted from greater PG volatility relative to VG and sensor losses. The correction factors (ratios 1-4) for PM2.5 were SMPS + APS data (4.96-7.62), MiniWRAS (2.02-3.64), pDR (0.50-1.07), and SidePak (0.22-0.40). These data can help improve ECIG aerosol measurement accuracy for different ECIG mixture ratios.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
08:33Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
Related Concept Videos
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Filtration
Electrogravimetric Analysis: Overview
To test the completeness of the...